Probe Configurations for Philips Affiniti CVx, ClearVue 650 and InnoSight
Target long-tail queries: Philips Affiniti CVx ClearVue 650 InnoSight probe configuration list up to 31 probes RFQ
These three Philips platforms share a probe ecosystem but not the same probe list. A configuration can hold up to 31 probe entries, so the exact set matters more than the console name.

Mapping the probe portfolio
Group the portfolio by clinical role: high frequency linear small-parts probes, curved abdominal probes, phased array cardiac probes, endocavitary probes and volume or 4D probes. The usual requests come from concrete damage, not from a wish list. A cracked acoustic lens, a dead element column that leaves a dark vertical stripe on a uniform phantom, or an endocavitary probe failing a leakage and electrical safety check are typical triggers. Run an element uniformity test and record which probe type and preset the fault appears on before you specify a replacement.
Why the console model still matters
ClearVue 650 and InnoSight are compact systems with different supported probe subsets, connector details and board revisions, while Affiniti CVx supports a broader cardiac and volume set. A probe PN valid on Affiniti CVx may stay dark on ClearVue 650 even when the connector seats, because installed options or licences and software differ between the two. That is the compatibility trap in RFQs that list only a family name. Confirm the supported matrix first, then select the specific probe from Spare parts or the Equipment listing.
Writing a usable RFQ
List each probe by PN in the format PN xxxxxx, serial number, type such as small-parts, cardiac, endocavitary or volume, console model, software version and installed option. State clearly whether you need one replacement probe or a full configured set, and attach a nameplate photo of each connector. A part number alone is not sufficient to guarantee compatibility across these three platforms. Our Maintenance team can check the set against your console, or send the whole list through Contact. Include the preset name and state clearly whether a volume licence is active on that console.
Frequently asked questions
How many probes can one console hold?
Up to 31 probe entries, but the supported subset depends on model, software and licensed options.
Can ClearVue 650 use an Affiniti CVx probe?
Only if the PN is in the supported matrix and the option is licensed; connector fit alone is not proof.
Do you unlock cardiac or volume options?
No. We supply probes as hardware and do not activate software options.
Related parts and models
Part numbers are reference identifiers taken from public catalogs. Confirm against the serial number, firmware version and installed options of your unit before ordering.